This table summarizes the cyclers, testers, and equipment that are currently compatible with Voltaiq.
|
Tester |
Version Requirement |
File format |
Not supported |
Notes |
|
Admiral |
2.08.29.2022 (or higher) |
CSV |
||
|
Arbin |
MITS7 |
.res |
SQL |
MITS7 has database write issues which can result in lagging data sync. |
|
Arbin |
MITS8-Pro (Supported only with the supplementary “Central Monitor and Control Solution” CMCS) |
CSV |
SQL |
Customers must also purchase the “CMCS” module from Arbin (not included by default) and have it installed on each computer by an Arbin rep. |
|
Arbin |
MITS4 |
.res |
Voltaiq supports MITS 4.27 Build 120209, and MITS 4.32 Build 160119. Contact Voltaiq Support for other builds. |
|
|
A&D |
iCentral |
.dat |
||
|
Bio-Logic |
EC-Lab® V10.02, V11.12, V11.21, V11.27, V11.42 |
.mpt, .mpr |
.mps |
Currently supported Techniques: OCV, GCPL, CV, CVA, PEIS, ZIR, GEIS, ModBat, CP, PCGA. Please inquire about any additional techniques. |
|
Bitrode |
Visual LCN |
CSV |
||
|
Digatron |
BTS-600 |
CSV |
Contact Voltaiq Support for other builds |
|
|
Innovex |
All known |
.ycd, CSV |
||
|
Landt |
V7.4.7.4 (or higher) |
CSV, XLS |
||
|
Maccor |
MIMS Server version 1.5 and 2.0 |
ASCII |
Raw Binary Indexed Binary |
|
|
Neware |
Please see below table for Software <> Hardware support for Neware XLS |
XLS |
.NDA |
|
|
Novonix |
2.2.0.1 |
CSV |
Voltaiq does not support version 2.2.0.2, but support is planned in the near-term roadmap. |
|
|
PEC |
BBS Pkg 1.29.0.0 BBS Pkg 1.32.0.2 |
CSV |
||
|
PNE |
All known |
CSV |
||
|
Toyo |
Voltaiq currently offers limited support for Toyo, please inquire additional information. |
For all listed softwares, there may be additional requirements such as specific software, hardware, or networking configurations. Voltaiq will support all necessary requirements for installation and will provide detailed information for each.
|
Neware XLS Importer Compatibility Table |
|||||||
|
6.8 |
7.4 |
7.6 |
8 |
8.2 |
9 |
9.1 |
|
|
3000 |
unknown | n/a | n/a | ||||
|
4000 |
unknown | no | no | no | no | n/a | n/a |
|
9000 |
unknown | n/a | n/a | n/a | n/a | yes | yes |
Many of our customers need to import data into the system from other sources, such as vehicle CANbus, un-supported commercial testers, custom battery testers, supplier generated data, modeling data, or remote/field data. For these use cases, Voltaiq provides a standard data format (VDF) as an export target. Data in this format can be imported into Voltaiq to be managed and analyzed alongside other data. Contact Voltaiq for more information.